SP-type
SP-type Inter-Connector consists of alternate layers of conductive and insulating rubber and of soft rubber insulators fitted on both sides. Since SP type has lower resistance than SS/SG, it is particularly ideal for display with tall height, such as LCD with backlight.
Outline Dimensions:
Dimensions and Tolerances:
Item | Unit | 0.05P type | 0.10P type | |
---|---|---|---|---|
Pitch | P | mm | 0.05±0.03 | 0.10±0.04 |
Length | L | mm |
2.0~20.0±0.15
20.1~90.0±0.65% 90.1~150.0±0.6 150.1~200.0±0.8
200.1~275.0±1.0 |
|
Height | H | mm |
1.0~5.0±0.1
5.1~20.0+0.15/-0.1
|
|
Width | W | mm |
1.2~2.3± 0.1
2.4~4.0±0.15
|
|
Width of conductive layer | Z | mm |
0.3±0.05
0.6±0.05
|
*H≧W/2
Basic Properties:
Item | Component | Unit | 0.05P type | 0.10P type |
---|---|---|---|---|
Specific gravity | Insulator Conductor Edge insulation part |
1.15 1.15 1.05 |
1.15 1.15 1.05 |
|
Shore hardness A | Insulator Conductor Edge insulation part |
ISO7619 (type A) |
65~73 60~65 20~25 |
65~73 60~65 20~25 |
Compression set | * | % | 15~20 | 12~18 |
Volume resistivity | Insulator Conductor Edge insulation part |
Ω/cm | 1 x 1014 1.3 8 x 1013 |
1 x 1014 1.3 8 x 1013 |
Dielectric breakdown voltage | Insulator Edge insulation part |
kV/mm | 23~27 23~27 |
23~27 23~27 |
Insulation resistance (500V DC) | * | MΩ | 1 x 103≦ | 1 x 103≦ |
Operating temperature range | ºC | -25~85 | -25~85 |
*The test is carried out with Shin-Etsu’s own method.
Compression Curves:
Note:
Every item or numerical value indicated herein is measured by Shin-Etsu and out of guarantee.
The quality of the connector, which has been already assembled, is out of guarantee.
Please make sure to see about the purpose/conditions of use and practice your own test. Industrial ownership like patent doesn’t guarantee the usage of the connector.
Every item or numerical value indicated herein is measured by Shin-Etsu and out of guarantee.
The quality of the connector, which has been already assembled, is out of guarantee.
Please make sure to see about the purpose/conditions of use and practice your own test. Industrial ownership like patent doesn’t guarantee the usage of the connector.